{"id":58827,"date":"2023-01-06T16:01:09","date_gmt":"2023-01-06T12:01:09","guid":{"rendered":"https:\/\/gmsgroup.ge\/?page_id=58827"},"modified":"2023-01-06T16:02:16","modified_gmt":"2023-01-06T12:02:16","slug":"joint-surgery-endoprosthesis-biotechni","status":"publish","type":"page","link":"https:\/\/gmsgroup.ge\/en\/joint-surgery-endoprosthesis-biotechni\/","title":{"rendered":"Joint Surgery &#038; Endoprosthesis &#8211; Biotechni"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<strong><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-58524 size-medium alignleft\" src=\"https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/1111-300x297.png\" alt=\"\" width=\"300\" height=\"297\" srcset=\"https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/1111-300x297.png 300w, https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/1111-150x150.png 150w, https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/1111.png 705w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Filler \u2013 3ND<\/strong><\/p>\n<ul>\n<li>Femoral stem for Total hip arthroplasty and hemiarthroplasty<\/li>\n<li>Version Titanium Press-fit stem with Porous Ti+HA coating in metaphysis and HA only in diaphysis.<\/li>\n<li>Version Stainless Steel to be Cemented, mirror-polished finish<\/li>\n<li>10 sizes (from 130 to 190mm lengths)<\/li>\n<li>135\u00b0 CCD angle for coated stems with or without collar, and cemented<\/li>\n<li>130\u00b0 CCD angle Varised and Lateralised (coated)<\/li>\n<\/ul>\n<p>12\/14 mini-taper cone compatible with all stainless steel and Biolox\u00ae Delta ceramic femoral heads from BIOTECHNI portfolio.[\/vc_column_text][vc_empty_space][vc_column_text]<strong><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-58533 size-medium alignright\" src=\"https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/2222-300x298.png\" alt=\"\" width=\"300\" height=\"298\" srcset=\"https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/2222-300x298.png 300w, https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/2222-150x150.png 150w, https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/2222.png 673w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>TTHR Easy<\/strong><\/p>\n<ul>\n<li>Revision femoral stem for hip prosthesis<\/li>\n<li>Monobloc right and left design<\/li>\n<li>Simplified instrumentation<\/li>\n<li>Titanium stem with Anatomical curvature of 1000mm radius, Porous Ti+HA coating in metaphysis and HA only in diaphysis<\/li>\n<li>4 metaphyseal sizes, 2 distal diameters 10 and 12mm, 4 lengths of 190, 240, 290 and 340mm<\/li>\n<li>Distal locking by fixation screws available for 12mm distal diam. stems from 240mm<\/li>\n<\/ul>\n<p>12\/14 mini-taper cone compatible with stainless steel and Biolox\u00ae Delta ceramic femoral heads from BIOTECHNI portfolio.[\/vc_column_text][vc_empty_space][vc_column_text]<strong><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-58536 size-medium alignleft\" src=\"https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/3333-248x300.png\" alt=\"\" width=\"248\" height=\"300\" srcset=\"https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/3333-248x300.png 248w, https:\/\/gmsgroup.ge\/wp-content\/uploads\/2023\/01\/3333.png 685w\" sizes=\"(max-width: 248px) 100vw, 248px\" \/>R<\/strong><strong>everse <\/strong><strong>S<\/strong><strong>houlder<\/strong><\/p>\n<p>\u2013\u00a0Complete reverse shoulder prosthesis solution, primary indication and revision<br \/>\n\u2013\u00a0Glenoid component of S 35, 40 and 45mm, porous Ti+HA coated, with extensible fixation plug, fixation screw<br \/>\n\u2013\u00a0Revision glenoid component with malleable fixing lugs S 35 only<br \/>\n\u2013\u00a0GEOsphere of variable diameter 35, 40 and 45mm<br \/>\n\u2013\u00a0UHMWPE insert of 2,4 and 8mm height additional spacer (+9mm) available<br \/>\n\u2013\u00a0Humeral epiphysis cemented or Ti+HA coated of S 35, 40 and 45mm<br \/>\n\u2013\u00a0Diaphyseal stem of variable size, 4 lengths and 5 diameters, cemented or HA coated<\/p>\n<p>Distal locking available by locking screw only on 150 and 180mm HA coated stems.[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Filler \u2013 3ND Femoral stem for Total hip arthroplasty and hemiarthroplasty Version Titanium Press-fit stem with Porous Ti+HA coating in metaphysis and HA only in diaphysis. Version Stainless Steel to be Cemented, mirror-polished finish 10 sizes (from 130 to 190mm lengths) 135\u00b0 CCD angle for coated stems with or without collar, and cemented 130\u00b0 CCD&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/pages\/58827"}],"collection":[{"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/comments?post=58827"}],"version-history":[{"count":1,"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/pages\/58827\/revisions"}],"predecessor-version":[{"id":58828,"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/pages\/58827\/revisions\/58828"}],"wp:attachment":[{"href":"https:\/\/gmsgroup.ge\/en\/wp-json\/wp\/v2\/media?parent=58827"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}